Configuring The Alert Tone (Alert Tone Pattern) - Kenwood NEXEDGE NX-200 Function Reference

Hide thumbs Also See for NEXEDGE NX-200:
Table of Contents

Advertisement

6 SOUND
6.2 Tones that Sound When the Transceiver Receives a Call
Configuration using KPG-111D/ DN
Configuring each Alert Tone (DTMF) (
Configuring the Alert Tone (2-tone) (
Configuring each Alert Tone (FleetSync) (
Configuring each Alert Tone (NXDN) (
Configuring the Alert Tone (Status/Short Message Call) (NXDN) (
Configuring the Alert Tone (Emergency Response) (NXDN) (

Configuring the Alert Tone (Alert Tone Pattern)

Alert Tone Pattern is the alert tone pattern when receiving a call with the optional signaling. An Alert Tone that is suitable
for a user's environment can be selected.
Alert Tone Pattern can be used to select an Alert Tone from 8 patterns of Alert Tones. An Alert Tone pattern consists of 16
tones.
Alert Tone Pattern can be configured by using KPG-111D/ DN. The following table shows the configuration items for the
Autodial List.
Alert Tone Pattern
The tone frequency can be configured. A frequency between 400 Hz and 2500 Hz can be configured in steps
Frequency
of 10 Hz. Gap can be configured if "No Tone" is selected.
The tone length can be configured. A tone length between 10 ms and 2500 ms can be configured in steps of
Length
10 ms. No tone sounds if 0 ms is configured.
This function can be used to configure the number of times for the Alert Tone that sounds from the
transceiver. A number from 1 to 255 can be configured. The Alert Tone sounds from the transceiver until it is
Cycle
manually stopped if "Infinite" is configured. If it is intended for the Alert Tone to sound multiple times, the Alert
Tone does not sound from the transceiver while the transceiver unmutes the speaker. Or, if the matching
state of Optional Signaling is reset, Alert Tone will also be disabled.
This function can be used to configure the timing to repeat the Alert Tone that sounds from the transceiver. A
Interval
time between 0 and 255 s can be configured in steps of 1 s.
Configuration using KPG-111D/ DN
Configuring the Alert Tone Pattern (
FUNC (K)/Ver 4.00
See
FPRG 8.14.2 Decode Tab)
See
FPRG 8.15.2 Decode (2-tone 1) to Decode (2-tone 4) Tabs)
See
FPRG 8.16.3 General 2 Tab)
See
FPRG 8.19.4 Trunking Tab and 8.19.5 Conventional Tab)
Table 6-10 Alert Tone Pattern
See
FPRG 8.27 Special Alert Tone Window)
See
FPRG 8.19.3 General 2 Tab)
See
FPRG 8.19.3 General 2 Tab)
Description
CONTENTS
INDEX
91

Advertisement

Table of Contents
loading

Table of Contents