22 FUNCTION PORTS
22.1 Universal Connector (Portable Only)
System
Analog Conventional System/
LTR Trunking System
NXDN Conventional System
NXDN Trunking System
The vibrator vibrates for 500 ms and stops for 500 ms, and repeats this cycle 10 times.
However, in the following cases, even if the above conditions are satisfied, the vibrator cannot be activated. During this
state, the "
" icon blinks.
When the transceiver receives another signal to match the Optional Signaling while the vibrator is activated after
the Optional Signaling matches.
During the amount of time configured for Auto Reset Timer after pressing the PTT switch, if the transceiver is on a
channel or GID where anything other than "None" is configured for Optional Signaling.
Pressing the Vibrator key toggles the Vibrator between enabled and disabled.
Vibrator can also be enabled or disabled by selecting "Vibrator" after entering Menu Mode by pressing the Menu key.
(Refer to
3.4 Using Menu Mode on page
Operating the Transceiver
1
Press the
Vibrator
The "
" icon appears and then Vibrator will be enabled. The
vibrator vibrates for a second.
2
Press the
Vibrator
The "
" icon disappears and then the Vibrator will be disabled.
Note
• The Vibrator is automatically enabled when the transceiver is turned ON if the Vibrator key is not configured while "Vibrator" is
configured for Universal Connector Pin Number 11. (Refer to
• The status of the Vibrator is retained even if the transceiver is turned OFF.
• The function assigned to a key (other than the Emergency key) that is pressed while the vibrator is vibrating cannot be activated.
• While the "
" icon blinks, the vibrator does not function even if the Optional Signaling match.
Configuration using KPG-111D/ DN
Assigning functions to the PF keys on the transceiver (
FUNC (K)/Ver 4.00
Table 22-2 Activation Conditions for Vibrator
• If the Optional Signaling match
• If the transceiver receives a Status Message (other than status 88, 90, 91 or 92)
• If the transceiver receives a Short Message
• If the transceiver receives a Paging Call
• If the Optional Signaling match
• If the transceiver receives a Status Message (other than status 226)
• If the transceiver receives a Short Message
• If the transceiver receives a Paging Call
• If the Unit ID or Group ID matches
• If the transceiver receives a Status Message (other than status 226)
• If the transceiver receives a Short Message
• If the transceiver receives a Paging Call
23.)