16 COMMUNICATIONS IN AN EMERGENCY
16.3 Automatically Transmitting and Receiving in Emergency Mode
16.3
Automatically Transmitting and Receiving in Emergency
Mode
The number of times for which the transceiver toggles between transmission and reception, or the duration for a single
session of automatic transmission or reception in Emergency Mode can be configured. It is also available to change the
microphone sensitivity for Emergency Mode or to multiplex the Background Tone on the audio to be transmitted.
Emergency Cycle
Emergency Cycle is the number of times for which the transceiver toggles between transmission and reception in
Emergency Mode.
Configuration
The transceiver repeats automatic transmission and automatic reception for the configured number of times, and
1 to 200
then the transceiver exits Emergency Mode.
The transceiver continues to alternate between automatic transmission and reception until the Emergency key is
Infinite
pressed again or the transceiver is turned OFF.
Off
The transceiver does not automatically transmit and receive in Emergency Mode.
Note
If "Off" is configured for Emergency Cycle and if "Selected" is configured for Emergency CH/GID Type, a zone-channel or GID can be
changed even while the transceiver is placed in Emergency Mode. However, a zone-channel or GID cannot be changed while
Emergency Alarm in an MDC-1200 format is activated.
Configuration using KPG-111D/ DN
Configuring the Emergency Cycle (
Transmit Duration
Transmit Duration is the duration for a single session of automatic transmission in Emergency Mode.
The transceiver switches to automatic reception in Emergency Mode when the time configured for Transmit Duration
elapses after the transceiver starts automatic transmission in Emergency Mode.
Configuration using KPG-111D/ DN
Configuring the Transmit Duration (
Receive Duration
Receive Duration is the duration for a single session of automatic reception in Emergency Mode.
The transceiver switches to automatic transmission in Emergency Mode when the time configured for Receive Duration
elapses after the transceiver starts automatic reception in Emergency Mode.
Configuration using KPG-111D/ DN
Configuring the Receive Duration (
FUNC (K)/Ver 4.00
Table 16-8 Emergency Cycle
Description
FPRG 8.28.1 Emergency 1 Tab)
See
FPRG 8.28.1 Emergency 1 Tab)
See
See
FPRG 8.28.1 Emergency 1 Tab)