16 COMMUNICATIONS IN AN EMERGENCY
16.1 Placing the Transceiver in Emergency Mode
16.1
Placing the Transceiver in Emergency Mode
The transceiver can be manually placed in Emergency Mode using the Emergency key.
Operating the Transceiver
 Placing the transceiver in Emergency Mode
1
Press and hold the
The transceiver enters Emergency Mode.
 Exiting Emergency Mode
1
Select one of the following operations.
• Press and hold the Emergency key for longer than the time configured for Emergency-key Delay Time while the transceiver
is in Emergency Mode.
• Turn the transceiver OFF.
Note
• The transceiver exits Emergency Mode if receiving an Emergency Termination Status (FleetSync: 88, NXDN: 226) while in Emergency
Mode.
• For Portable, "Emergency" can be assigned to the AUX key or the PF 1 key of the speaker microphone.
• For Mobile, "Emergency" can be assigned to the Triangle key.
Configuration using KPG-111D/ DN
Assigning functions to the PF keys on the transceiver (
Emergency-key Delay Time
Emergency-key Delay Time is the duration from when the Emergency key is pressed until the transceiver enters
Emergency Mode. Pressing and holding the Emergency key for the duration configured for Emergency-key Delay Time
causes the transceiver to enter Emergency Mode. This function can be used to prevent the transceiver from erroneously
entering Emergency Mode.
Configuration using KPG-111D/ DN
Configuring the Emergency-key Delay Time (
Emergency Alarm (MDC-1200 Only)
Emergency Alarm is a function to send an Emergency Alarm Request message before the transceiver enters Emergency
Mode to notify the base station that the transceiver is in an emergency situation.
Using this function can reliably notify the base station that the transceiver is in an emergency situation.
If the Emergency key is pressed and held for longer than the time configured for Emergency-key Delay Time on an analog
channel or GID where MDC-1200 is used as the signaling type, the transceiver sends the Emergency Alarm Request
message using the emergency packet in the MDC-1200 format. Upon receipt of an acknowledgment, the transceiver
enters Emergency Mode.
FUNC (K)/Ver 4.00
Emergency
key for longer than the time configured for Emergency-key Delay Time.
See
FPRG 8.28.1 Emergency 1 Tab)
See
FPRG 8.12 Key Assignment Window)