INTAKE (INDUCTION)
CAUTION:
When installing the NOZZLE BRKT, hold the
NOZZLE BRKT while tightening so that it does
not rotate.
NOTE:
• When the ambient temperature is 15°C (59°F) or
less, heat the entire part of double-sided tape and
the attachment area to approx. between 25°C and
40°C (77°F and 104°F) using a heat light, etc.
• Heating a particular small area will cause defor-
mation of the parts.
(1) Clean and degrease the attachment area of
NOZZLE BRKT on the duct - inner front hood.
(2) Peel off a half of the backing sheet (a) of
NOZZLE BRKT, and attach the masking tape
(b).
(a)
(b)
(3) Temporarily install the NOZZLE BRKT with
bolts.
(4) Adjust the position so that the center of the
bolt (a) and the center of the attachment area
(b) align in a straight line.
(b)
(a)
Intercooler Water Spray Nozzle
(a)
(b)
AA-14031
AA-14032
(b)
(a)
AA-14033
IN-22
(5) Pull the masking tape attached in step (2) to
remove the backing sheet, and press-fit the
NOZZLE BRKT.
(6) Tighten the bolts temporarily installed in
step (3).
Tightening torque:
4.5 N·m (0.5 kgf-m, 3.3 ft-lb)
3) Thereafter, install in the reverse order of remov-
al.
NOTE:
When it is hard to install the intercooler water spray
nozzle, insert the intercooler water spray nozzle by
attaching one claw at a time.
C: INSPECTION
1) Check the intercooler water spray nozzle for
clogging.
2) Check that the intercooler water spray nozzle
has no deformation, cracks or other damages.
3) Check that the hose has no cracks, damage or
loose part.