Xd03, Motor Connection - Bosch rexroth ctrlX SAFETY SafeMotion Applications Manual

Table of Contents

Advertisement

13.3.2

XD03, motor connection

Important information
Connectors not included in scope of delivery.
Installation instructions
The specified connection cross sections are the cross sections that can be
connected. Size the required cross section of the connection lines according to
the occurring current load.
R911404905, Edition 02
Lethal electric shock due to live parts with more than 50
WARNING
V!
Only operate the device
with connected connectors (even if no lines are con-
nected to the connectors) and
with connected equipment grounding conductor!
Risk of damage to the device!
NOTICE
Provide strain relief for the terminals of the device in the
control cabinet.
Provide for optimum shield contact of the motor power cable.
For the connection between drive controller and motor, use our ready-made
motor power cables, where possible.
ctrlX SAFETY "SafeMotion"
Motor connections
Bosch Rexroth AG
261 / 302