Bosch rexroth ctrlX SAFETY SafeMotion Applications Manual page 108

Table of Contents

Advertisement

ctrlX SAFETY "SafeMotion"
108 / 302
Transition functions
Fig. 40: Monitoring function 2a: "SS2, standstill-prioritized with NC-controlled
transition (with trend monitoring) (with NC-Ready)"
P‑0‑3255
P‑0‑3280.0.2 SMO: Max. Transition time normal oper. to safe standstill
P‑0‑3280.0.3 SMO: Max. Transition time between safe operating states
Monitoring function 2b: "SS2, standstill-prioritized with NC-controlled transi-
tion (based on actual velocity)"
When the monitoring function 2b [SS2, standstill-prioritized with NC-controlled
transition (based on actual velocity)] has been configured, the axis is deceler-
ated in an NC-controlled way when SS2 is selected; i.e. the higher-level control
unit decelerates the drive via the command value system.
To monitor the standstill process, the transition function "Safe stop 2 (SS2)"
calls the
actual
Safely-monitored deceleration " is reported and the drive is set to standstill
according to the parameterized error reaction (P‑0‑3263.0.1) (see
tion and escalation
The currently active velocity monitoring limit of Safe Motion is displayed in
"P‑0‑3238, SMO: Active velocity threshold. With this parameter it is possible to
check in the control unit whether the velocity command values are within the
allowed limits.
With the auxiliary function
sible to monitor and, if necessary, limit the velocity command value effective in
the drive to the active velocity threshold (P‑0‑3238).
In
the deceleration process is completed within the parameterized tran-
sition
completed within the parameterized transition time, the error "F7050
Maximum transition time exceeded" is signaled. The drive keeps being deceler-
ated in accordance with the parameterized error reaction (P-0-3263.0.1) (see
⮫ Error reaction and escalation
Bosch Rexroth AG
SMO: Velocity threshold for Safe standstill
⮫ Transition function "Safely-monitored deceleration based on
velocity". If the SMD detects an exceeded velocity, the error "F7051
strategy).
parallel
with
velocity
time
(P-0-3280.0.2
"⮫ limitation of the positioning
monitoring,
the
SMD
or
P-0-3280.0.3).
If
strategy).
⮫ Error reac-
velocity", it is pos-
also
monitors
that
the
transition
is
not