– Disconnect the plug connection -A- from the gearshift mech‐
anism.
– Unscrew the screws -arrows- from the shift housing.
Continued for all vehicles
– Remove air filter ⇒ Engine; Rep. gr. 24 or ⇒ Engine; Rep.
gr. 23 .
– Expose the selector lever control cable -A- from the gearbox
shift lever with the removal tool for the inner lining of the door
panel -MP8-602/1- .
– Remove lock washer -arrow- of the selector lever control cable
and leave the selector lever control cable must be left in the
fitting position.
Note
The lock washer -arrow- of the selector lever control cable
must always be replaced ⇒ Electronic Catalogue of Original
Parts .
Do not bend or buckle selector lever control cable.
Do not press the selector lever control cable out of the cable
support towards the rear. The selector lever control cable is
only guided out of the cable support when removing the gear‐
shift mechanism.
– Raise vehicle.
Fabia II 2007 ➤ , Fabia II 2009 ➤ , Fabia II 2011 ➤ , Octavia II 2004 ➤ ...