Program mode
PROG P7–2: KARMA 2
7–2–1: GE RTP
(GE Real-Time Parameters)
7–2
–1a
7–2
–1b
Here you can edit the parameters of the GE selected for the
KARMA module. If you assign GE parameters to the
KARMA Sliders or KARMA Switches 1–8, you'll be able to
control the generated phrases and patterns in realtime.
7–2–1a: GE Number & Name, GE RTC
Select, Tempo
GE Number & Name
This shows the GE selected for the Module. For more
information, please see "0–5c: GE Select" on page 5.
GE RTC Select
This switches the GE realtime parameter display.
1–8, 9–16, 17–24, 25–32: Respectively display GE realtime
parameters 1–8, 9–16, 17–24, and 25–32.
(Tempo)
For more information, please see " (Tempo)" on page 3.
7–2–1b: GE Real-Time Parameters
GE RT Parm 1–8, 9–16, 17–24, 25–32:
Each GE has up to 32 preset parameters for controlling the
phrase or pattern, referred to as GE Real-Time Parameters
(or GE RTP). The specific parameters, and the available
value ranges, will vary depending on the selected GE.
For details on the individual GE Real-Time parameters,
please see "KARMA GE guide" on page 525.
GE RT PARAM (GE Real-Time Parameter)
Each of the GE Real-Time Parameters has a basic value, a
controller assignment with polarity, and minimum and
maximum values (for setting the range of the selected
controller).
When you select a new GE, the basic, minimum, and
maximum values will be reset to the values saved in the GE,
and the controller assignment will be set to the defaults for
the GE's RTC Model.
For details on the individual GE Real-Time parameters,
please see "KARMA GE guide" on page 525.
90
7–2
–1
Menu
[1-8, 9-16, 17-24, 25-32]
[040.00...300.00, EXT]
MIN (GE Real-Time Parameter Minimum Value)
This sets the parameter value when the selected controller is
at its minimum point—for instance, when a slider is at the
bottom of its throw. Note that you can reverse the action of
the controller by setting this to be higher than the MAX
value, below.
The available values will depend on the GE Real-Time
parameter.
MAX (GE Real-Time Parameter Maximum Value)
This sets the parameter value when the selected controller is
at its maximum point—for instance, when a slider is at the
top of its throw.
The available values will depend on the GE Real-Time
parameter.
VALUE (GE Real-Time Parameter Value)
This sets the basic value of the GE parameter, which
corresponds to the center position of the controller. It must
be within the MIN and MAX values.
ASSIGN (GE Real-Time Parameter Assign)
[---, SL1...SL8, SL1s...SL8s, SW1...SW8, Dyn1...Dyn8]
Here you can assign the controller for the GE Real-Time
parameter.
By assigning GE Real-Time Parameter to KARMA Real-Time
Controls, they can be controlled in real-time while you play.
---: No assignment.
SL1...SL8 (Slider1...8): Assign the parameter to KARMA
Sliders 1–8. The slider will continuously control the "value."
For example, let's assume that the Rhythm Swing%
parameter of the selected GE is set to a MIN of +0000, and a
MAX of +0100.
• If you set "Value": +0050, "Assign": SL1, and Polarity:+
Slider 1 at the center position will produce a value of
+0050. At minimum the value will be +0000, and at maxi-
mum the value will be +0100. Turning the Slider from
center toward the minimum will control the value from
+0050...+0000, and turning it from center toward the
maximum will control the value from +0050...+0100.
• If you set "Value": +0080, "Assign": Slider 1, and
"Polarity":+
Slider 1 at the center position will produce a value of
+0080. At minimum the value will be +0000, and at far
maximum the value will be +0100. Turning the slider
from center toward the minimum will control the value
from +0080...+0000, and turning it from center toward
the maximum will control the value from +0080...+0100.
SL1s...SL8s (Slider SW 1...8): Assign the parameter to
KARMA Sliders 1–8. The Slider will switch the value
between minimum and maximum only. The minimum to
center range of the Slider is off, and the center to maximum
is on.
• If you set "Value": +0050, "Assign": Slider (SW) 1, and
Polarity:+
Turning the slider toward the minimum will produce a
value of +0000. Turning it to center or maximum will pro-
duce a value of +0100.
SW1...SW8: The parameter will be assigned to switches 1–8.
The minimum is off, and the maximum is on.
[–5000...+5000]
[–5000...+5000]
[–5000...+5000]