Cross connecting telephones

553-3021-209
Standard 1.00
Chapter 17 — Connecting the telephones
Before you continue, install the cable from the slot that contains the line card
associated with the telephone being connected. Refer to "Chapter 13 —
Installing and connecting the cross-connect terminal" on page 229, if you
require additional cable installation.
Always use caution when installing or modifying telephone lines. Do
not install telephone wiring during a lightning storm. Do not install
telephone jacks in wet locations unless the jack is designed for wet
locations. Never touch uninsulated telephone wiring unless the line is
disconnected at the network interface.
Connect the telephones according to Figures 67 and 68.
Procedure 63
Cross connecting telephones
1
Locate the telephone terminations at the cross-connect terminal.
2
Connect the Z-type cross-connect wire to the leads of the
telephone.
3
Locate line circuit card (TN) terminations at the cross-connect
terminal.
4
Connect the other end of the cross-connect wire to the assigned
TN terminal block.
5
For installations in Germany, attach a BZT approval label to the
bottom of the telephone. Refer to "Appendix B – Additional
information for installations in Germany" on page 411 for a listing
of BZT approval labels.
—————————— End of Procedure ——————————