Chapter 12 — Installing the circuit cards
Trunk Data Block
Use Overlay 14 to configure each of the trunk units on the NTAG04AA
CO/DID card.
LD 14 - Route Data Block
Prompt
Response
REQ
NEW
TYPE
COT
TN
CC UU
CDEN
(8D)
XTRK
XCOT
(see note)
SIGL
EAM
STRI
IMM
STRO
IMM
SUPN
YES
PPID
07
CLS
DTN, (DIP)
BARD
DTCR
YES, (NO)
Note: This prompt is required only for the first unit defined on each
NTAG04AA card.
Self-test
When the card is installed, the red Light Emitting Diode (LED) on the
faceplate flashes as the self-test runs. If the self-test completes successfully,
the card is automatically enabled (if the card has been configured in software)
and the LED goes out. If the self-test fails, the LED remains lit. The LED also
remains lit if one or more units on the card become disabled while the card is
operating.
Comments
Define a new trunk unit
Central Office Trunk
Terminal number of the unit:
Card, Unit
Card density is 8D (default)
Type is IPE COT
E&M signaling
Incoming start immediate
Outgoing start immediate
Answer and disconnect supervision
PPM country Identification
Digitone signaling, (Digipulse)
Barring denied
Digit collection ready. Set to YES only
if class of service (CLS) is digitone
(DTN).
Option 11C Mini
Planning and Installation Guide
Page 207 of 590