Page 170 of 590
NT5K96JB/NT5K02JB Flexible analog line card
553-3021-209
Standard 1.00
Chapter 12 — Installing the circuit cards
The NT5K02JB line card is equipped with message waiting, while the
NT5K96JB is offered without message waiting.
Switch settings
There are no option switches on this card. Configure all settings in software.
Procedure 32
NT5K96JB / NT5K02JB Flexible analog line card installation
1
Insert the card in its allocated card slot.
2
Connect the line card units to the cross-connect terminal and
telephone by tip and ring leads.
3
Configure the telephone lines in software (LD 10).
—————————— End of Procedure ——————————
Self-test
The faceplates of the NT5K96JB and NT5K02JB cards have a red LED. The
LED lights when all of the assigned units on the circuit card are disabled.
July 1999