Chapter 12 — Installing the circuit cards
Trunk Data Block
Use Overlay 14 to configure each of the four trunk units on the NT5K36AB
DID/DOD trunk card. In the Overlay tables, default values are in parenthesis.
LD 14 - Route Data Block
Prompt
Response
REQ
NEW
TYPE
DID
TN
CC UU
XTRK
XDID
(see note)
SIGL
EAM
STRI
IMM
STRO
IMM
SUPN
NO
CLS
SHL, (LOL)
Note: These prompts are required only for the first unit defined on each
NT5K36AB card.
Self-test
When the card is installed, the red Light Emitting Diode (LED) on the
faceplate flashes as the self-test runs. If the self-test completes successfully,
the card is automatically enabled (if the card has been configured in
software). The LED goes out. If the self-test fails, the LED remains lit.
Comments
Define a new trunk unit
Direct Inward Dial
Terminal number of the unit in Option
11 format
Card, Unit
Type is IPE DID
EAM type signaling
Incoming start is immediate dial
Outgoing start is immediate dial
Answer and disconnect supervision
required
Attenuation pads in, (out)
Option 11C Mini
Planning and Installation Guide
Page 215 of 590