Nt5K18 Exchange Line Trunk Card Terminations - Nortel Meridian 1 Planning And Installation Manual

Table of Contents

Advertisement

Page 330 of 590

NT5K18 Exchange line trunk card terminations

553-3021-209
Standard 1.00
Chapter 18 — Connecting the trunks
Table 59
NT5K17 DDI cross-connect terminations (Continued)
Pair
Pins
T6
38
R6
13
39
14
T7
40
R7
15
41
16
Cross connect the NT5K18 Exchange line trunk card as shown in the
Table 60.
Note: The connections on the NT5K18 Exchange line trunk card are
polarity sensitive. Make sure the ground side of the trunk is connected to
the A leg of the NT5K18 circuit. Make sure the -50 volt side of the trunk
is connected to the B leg of the NT5K18 circuit.
Table 60
NT5K18 Exchange line trunk card cross-connect terminations
Pair
Pins
T0
26
R0
1
27
2
T1
28
R1
3
29
4
July 1999
Pair color
Unit number
BK-G
G-BK
Unit 6
BK-BR
BR-BK
BK-S
S-BK
Unit 7
Y-BL
BL-Y
Pair color
Unit number
W-BL
BL-W
Unit 0
W-O
O-W
W-G
G-W
Unit 1
W-BR
BR-W

Advertisement

Table of Contents
loading

This manual is also suitable for:

Option 11c mini

Table of Contents