Chapter 12 — Installing the circuit cards
Table 25
E&M Trunk card switch settings
Signaling
4-wire Type II
4-wire Type I
2-wire Type I
CEPT L1
AC15
RAN
MUS
PAG
4-wire Type V (BPO)
2-wire Type V (BPO)
LD 16 - Route Data Block
Prompt
Response
REQ
NEW
TYPE
RDB
CUST
0-99
ROUT
0-511
TKTP
TIE, RAN, PAG
ICOG
IAO
ACOD
XX
Switch Setting (J1.x)
Pins 1-2
Closed
Open
Comments
Define a new Route Data Block
Enter customer number
Enter route number
Define the trunk type as TIE,
Recorded announcement or Paging
Incoming and Outgoing trunk
XX=Trunk route access code
Option 11C Mini
Planning and Installation Guide
Page 149 of 590
Pins 2-3
Open
Closed