Nortel Meridian 1 Planning And Installation Manual page 73

Table of Contents

Advertisement

Chapter 4 — Creating an equipment layout plan and a card slot assignment plan
Figure 8
Typical layout for a installing the chassis on a wall in a horizontal position
Leave at least
2 in. (51 mm)
between edge
of backboard
and corner of room
Maximum of
21 in. (533 mm)
Minimum of
12 in. (305 mm)
Make sure power outlets are within reach of each system chassis. See
Table 1 on page 18 for cable and wire specifications.
Allow 24 in. (610 mm) at the top
for miscellaneous equipment
Draw 2 vertical lines
18.5 in. (470 mm)apart
10 in. (254 mm)
Recommended lowest position
for chassis installation is
10 in. (254 mm) from floor
Note: Leave wall space for the cross-connect terminal.
P ow e r
F a n
M a i n
s i s
OR KS
NE TW
C h a s
P ow e r
s i s
F a n
C h a s
n d e r
E x p a
OR KS
NE TW
Each chassis measures
8.4 in. x 17.2 in. x 12.8 in.
(213 mm x 437 mm x 325 mm)
Option 11C Mini
Page 53 of 590
Draw horizontal line
for bottom hole of
ear bracket
Distance from
edge of backboard
to isolated
ground outlet
0 - 27 in. (686 mm)
12 in. (305 mm)
553-9034
Planning and Installation Guide

Advertisement

Table of Contents
loading

This manual is also suitable for:

Option 11c mini

Table of Contents