NTCK22AA Direct Inward Dial / TIE trunk card

Switch settings
The NTCK22AA card does not have any option switches. Configure all
settings in software.
Procedure 49
NTCK22AA Direct Inward Dial / TIE trunk card installation
1
Insert the card into the selected card slot and lock it in position.
2
Connect the trunk units to the cross-connect terminal by tip and
ring leads (Refer to "Chapter 18 — Connecting the trunks" on
page 313).
3
Configure the card in software (LDs 16 and 14).
—————————— End of Procedure ——————————
LD 16 - Route Data Block
Prompt
REQ
TYPE
CUST
ROUT
TKTP
ICOG
ACOD
CNTL
TIMR
PRDI
see note
EOS
Note: If a partial dial time out is not required, press Carriage Return at
this prompt, <CR>, to accept the default.
Chapter 12 — Installing the circuit cards
Response
Comments
NEW
RDB
Define a new Route Data Block
0-99
Enter customer number
0-511
Enter route number
DID
Trunk type is Direct Inward Dial
ICT
Incoming only trunk
XX
XX=trunk route access code
YES
Change controls or timers
ICF 0
Set Incoming Flash timer to 0 ms
YES, (NO)
Partial dial time-out required,
(Disabled)
YES
Send End of Selection (number
received) signal