Chapter 12 — Installing the circuit cards
Trunk Data Block
Use Overlay 14 to configure each of the trunk units on the NT5K82HA
Central Office trunk card. In the Overlay tables, default values are in
parenthesis.
Overlay 14 - Trunk Data Block—NT5K82HA
Prompt
Response
REQ
NEW
TYPE
COT
TN
CC UU
XTRK†
XCOT
CDEN
(8D)
SIGL
LOP
SEIZ
YES
PPID
6
BTID
<cr>
CLS
XBTS
DTN, (DIP)
Self-test
When the NT5K82HA is installed and power is applied to it, a self-test is
performed on it. The red LED on the faceplate flashes three times, then
remains continuously lit until the cards are enabled in software. If the self-test
fails, the LED remains lit.
July 1999
Comments
Define a new unit
Central Office Trunk
Terminal number of the unit in Option
11 format:
Card number, Unit number
Type is IPE COT
Only required for the first unit to be
defined for that pack.
Card Density is 8D (default)
Loop Start Signaling
Enable Autoguard Supervision
PPM ID
Busy Tone ID not supported
Busy Tone Supervision Disabled, Busy
Tone Detection not supported
Digitone (Digitpulse) Signaling