Nortel Meridian 1 Planning And Installation Manual page 238

Table of Contents

Advertisement

Page 218 of 590
553-3021-209
Standard 1.00
Chapter 12 — Installing the circuit cards
Trunk Data Block
Use Overlay 14 to configure each of the trunk units on the NT5K84AA DID
trunk card.
LD 14 - Route Data Block
Prompt
Response
REQ
NEW
TYPE
DID
TN
LL SS CC UU
XTRK
XDID
(see note)
SIGL
EAM
SUPN
YES
CLS
SHL, (LOL)
Note: This prompt is required only for the first unit defined on each
NT5K84AA card.
Self-test
When the card is installed, the red Light Emitting Diode (LED) on the
faceplate flashes as the self-test runs. If the self-test completes successfully,
the card is automatically enabled (if the card has been configured in
software). The LED goes out. If the self-test fails, the LED remains lit.
July 1999
Comments
Define a new trunk unit
Direct Inward Dial
Terminal Number of the unit:
Loop, Shelf, Card, Unit
Type is IPE DID
E&M signaling
Answer and disconnect supervision
required
Attenuation pads in, (out)