Nt5K48Aa/Ba/Da Tone Detector Card - Nortel Meridian 1 Planning And Installation Manual

Table of Contents

Advertisement

Page 226 of 590

NT5K48AA/BA/DA Tone Detector card

553-3021-209
Standard 1.00
Chapter 12 — Installing the circuit cards
Self-test
When the card is installed, the red Light Emitting Diode (LED) on the
faceplate flashes as the self-test runs. If the self-test completes successfully,
the card is automatically enabled (if the card has been configured in
software). The LED goes out. If the self-test fails, the LED remains lit. The
LED also remains lit if one or more units on the card become disabled while
the card is operating.
Switch settings
The NT5K48 card does not have any option switches. Configure all settings
in software.
Procedure 51
Installation of the NT5K48AA/BA/DA Tone Detector card
1
Insert the card into the selected card slot and lock it in position.
2
Configure the country-specific tones in software (LD 97).
—————————— End of Procedure ——————————
Typical country-specific tone settings
Figure 47
CIS/Denmark
Characteristic
Frequency Band
Minimum Detect Level
Minimum Validation Time
Break Tolerance
Cadence Type
Second Stage Configuration
Minimum Acceptance Level
July 1999
Mnemonic in
Setting
Overlay 97
DFQ
1
MDL
-34 dBm0
MVT
1500 mS
BRK
000 mS
CAD
00
SSC
See Note
MINL
-45 dBm