Chapter 4 — Creating an equipment layout plan and a card slot assignment plan
553-3021-209
Standard 1.00
Note 1: Install the NT6D70 SILC card in the Main Chassis (Slots 1, 2,
or 3) if it is used as a clock controller.
If you use NE-A25B cables instead of NTAK19AA and NTAK19BA
cables with the NTAK02 and NTAK03 cards, continue with caution.
NE-A25B cables are not wired out to station equipment or trunk
circuits. NE-A25B cables can only be wired out to SDI circuits.
Make sure to first allocate the cards that you must install in the Main Chassis.
Fill the remaining card slots as required.
If you plan on using the preassigned numbering plan with consecutive
numbers, make sure you assign all line cards in consecutive card slots.
See Figures 12 and 13 for the card slot assignments in the Main Chassis and
Chassis Expander.