NT5K72AA E&M TIE trunk card
553-3021-209
Standard 1.00
Chapter 12 — Installing the circuit cards
Trunk Data Block
Use Overlay 14 to configure each of the trunk units on the NT5K50AA E&M
trunk card. In the Overlay tables, default values are in parenthesis.
LD 14 Route Data Block
Prompt
Response
REQ
NEW
TYPE
TIE, RAN, PAG
TN
CC UU
XTRK
XFEM
(see note)
SIGL
EM4, EAM,
EMTY
TY1, (TY2)
STRI
IMM, WNK, DDL Incoming start Immediate, Wink,
STRO
IMM, WNK, DDL Outgoing start immediate, Wink,
SUPN
YES, (NO)
CLS
DTN, (DIP)
Note: These prompts are required only for the first unit defined on each
NT5K50AA card.
Self-test
When the NT5K50AA card is installed and power is applied to it, a self-test
is performed on the card. The red LED on the NT5K50AA faceplate flashes
three times, then remains continuously lit until the card is enabled in software.
If the self-test fails, the LED remains lit after the card is enabled.
This trunk card provides four trunks which can function as 4-Wire E&M
(Type 1 and 2), RAN, PAG, and MUS.
July 1999
Comments
Define a new trunk unit
Trunk type TIE, (Recorded
announcement), (Voice paging)
Terminal number of the unit:
Card, Unit
Type is IPE XFEM
4 wire E&M, 2-wire E&M,
Type 1signaling, (Type 2)
Also use TY1 for Type V or BPO
Delayed dial
Delayed Dial
Answer and disconnect supervision
Digitone, (Dialpulse)