NT5K02SA / NT5K96SA Flexible analog line card

The NT5K02SA and NT5K96SA circuit cards are exactly the same except for
the message waiting feature: the NT5K02 card has a flashing low voltage
message waiting signal, while the NT5K96 card does not.
Procedure 29
NT5K02SA / NT5K96SA Flexible analog line card installation
1
Insert the card in its allocated card slot.
2
Connect the line card units to the cross-connect terminal and
telephone by tip and ring leads.
3
Configure the telephone lines in software (LD 10).
—————————— End of Procedure ——————————
Flash time configuration
Configure flash times in Overlay 97. You can configure the flash timers with
one of two sets of values, as shown in the table below.
Note: All prompts default except for those shown in the table.
LD 97 - Flash Timer Configuration
Prompt
REQ
TYPE
INTN
FLSH
Self-test
The faceplates of the NT5K02SA and the NT5K96SA cards have a red LED.
The LED lights when all of the assigned units on the circuit card are disabled.
Chapter 12 — Installing the circuit cards
Response
Comments
CHG
SYSP
YES
System is A-law
45 140
For sets with a flashhook button
45 1050
For sets without a flashhook button
Note: This is a system wide
parameter, and cannot be changed for
individual sets.