Nortel Meridian 1 Planning And Installation Manual page 219

Table of Contents

Advertisement

Chapter 12 — Installing the circuit cards
Trunk Data Block
Use Overlay 14 to configure each of the trunk units on the NT5K99AA and
NT5K99BA Central Office trunk cards.
Note: Press Carriage Return, <CR>, to accept the default for all
prompts, except for those shown in the following Overlay table. In the
Overlay tables, default values are in parenthesis.
LD 14 - Trunk Data Block
Prompt
Response
REQ
NEW
TYPE
COT
TN
CC UU
XTRK
XCOT
(see note)
CDEN
(8D)
SIGL
LOP
PPID
04 or <cr>
(see note)
CLS
SHL, (LOL)
DTN, (DIP)
BAT, (XBAT)
Note: This prompt is required only for the first unit defined on each
NT5K99AA or NT5K99BA card.
Self-test
When the NT5K99AA and NT5K99BA trunk cards are installed and power
is applied to them, a self-test is performed on each card. The red LED on the
faceplate flashes three times, then remains continuously lit until the card is
enabled in software. If the self-test fails, the LED remains lit.
Comments
Define a new trunk unit
Central Office Trunk
Terminal number of the unit in Option
11 format:
Card number, Unit number
Type is IPE COT
Card density is 8D (default)
Loop Start signaling
PPM ID is 04 for Spain; skip if PPM is
not to be configured
Attenuation Pads In, (Out)
Digitone signaling, (Digipulse)
Battery supervision enabled,
(disabled)
Option 11C Mini
Planning and Installation Guide
Page 199 of 590