Nortel Meridian 1 Planning And Installation Manual page 185

Table of Contents

Advertisement

Chapter 12 — Installing the circuit cards
3
Connect the trunk units to the cross-connect terminal by tip and
ring leads (Refer to the Tables in "Chapter 18 — Connecting the
trunks" on page 313).
4
Configure the card in software (LDs 16 and 14) .
—————————— End of Procedure ——————————
LD 16 - Route Data Block
Prompt
Response
REQ
NEW
TYPE
RDB
CUST
0-99
ROUT
0-511
TKTP
TIE, RAN, PAG
ICOG
IAO
ACOD
XX
Trunk Data Block
Use Overlay 14 to configure each of the trunk units on the NT5K83HA E&M
trunk card. In the Overlay tables, default values are in parenthesis.
LD 14 - Route Data Block
Prompt
Response
REQ
NEW
TYPE
TIE, RAN, PAG
TN
CC UU
XTRK
XFEM
(see note)
SIGL
EM4, EAM, WR4 4 wire E&M, 2-wire E&M,
EMTY
TY1, (TY2)
Comments
Define a new Route Data Block
Enter customer number
Enter route number
Define the trunk type as TIE,
Recorded announcement or Paging
Incoming and Outgoing trunk
XX=Trunk route access code
Comments
Define a new trunk unit
Trunk type TIE, (Recorded
announcement), (Voice paging)
Terminal number of the unit:
Card, Unit
Type is IPE XFEM
CEPT L1 AC15 signaling
Type 1 signaling, (Type 2)
Option 11C Mini
Planning and Installation Guide
Page 165 of 590