Download Print this page

Toshiba e-STUDIO556 Service Manual page 1303

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO556:

Advertisement

05/08
Mode
Element
Sub
element
08
Setting
Process
Fuser
Low-temperature
Mode
waiting
08
Setting
Process
Fuser
Low-temperature
Mode
waiting
e-STUDIO557/657/757/857
Item
Subitem
Code Sub-
Starting temperature
2239
while the temperature
is being raised
Starting temperature
2239
while the temperature
is being raised
Details
Default
Acceptable
code
value
value
0
Thick1(Low
Refer to
0~12
temperature
contents
environment)(Temper
ature
addition:Disable)
1
Thick1(Low
Refer to
0~12
temperature
contents
environment)(Temper
ature addition:Enable)
18
RAM
Contents
M
Sets the temperature to be added to the setting
contents of the code 08-5412 in the low-temperature
warming-up control mode.
0: 130℃ 1: 135℃ 2: 140℃ 3: 145℃ 4: 150℃ 5:
155℃ 6: 160℃ 7: 165℃ 8: 170℃ 9: 175℃ 10:
180℃ 11: 185℃ 12: Disabled
<Default value>
e-STUDIO557: 5
e-STUDIO657:
JPC/TWD: 5
Others: 7
e-STUDIO757/857:
JPC: 7
Others: 8
* The setting value of this code is applied when "0"
(disable) is set to the code 08-2226-3.
M
Sets the temperature to be added to the setting
contents of the code 08-5412 in the low-temperature
warming-up control mode.
0: 130℃ 1: 135℃ 2: 140℃ 3: 145℃ 4: 150℃ 5:
155℃ 6: 160℃ 7: 165℃ 8: 170℃ 9: 175℃ 10:
180℃ 11: 185℃ 12: Disabled
<Default value>
e-STUDIO557: 5
e-STUDIO657: 10
e-STUDIO757/857: 11
* The setting value of this code is applied when "1"
(enable) is set to the code 08-2226-3.
Proce
Servic
dure
e UI
4
4

Advertisement

loading