05/08
Mode
Element
Sub
element
08
Setting
Process
Fuser
Low temperature
Mode
waiting
08
Setting
Process
Fuser
Pre-running period
Mode
end temperature
08
Setting
Process
Fuser
Pre-running period
Mode
end temperature
08
Setting
Process
Fuser
Low-speed pre-
Mode
running starting
temperature during
ready status
08
Setting
Process
Fuser
Low-speed pre-
Mode
running stopping
temperature during
ready status
e-STUDIO557/657/757/857
Item
Subitem
Code Sub-
Temperature setting
2088
Pressure roller
2105
Pressure roller
2117
Pressure roller
2122
Pressure roller
2123
Details
Default
Acceptable
code
value
value
OHP film
Refer to
0~12
contents
Low temperature
Refer to
0~16
contents
Normal temperature /
Refer to
0~16
Option installed
contents
When options are
16
0~16
installed
When options are
2
0~9
installed
10
RAM
Contents
M
Sets the temperature at which low-temperature
warming-up control starts.
0: 130℃ 1: 135℃ 2: 140℃ 3: 145℃ 4: 150℃ 5:
155℃ 6: 160℃ 7: 165℃ 8: 170℃ 9: 175℃ 10:
180℃ 11: 185℃ 12: Disabled
<Default value>
e-STUDIO557: 5
e-STUDIO657/757/857: 6
M
0: 100°C 1: 110°C 2: 120°C 3: 125°C 4: 130°C 5:
135°C 6: 140°C 7: 145°C 8: 150°C 9: 155°C 10:
160°C 11: 165°C 12: 170°C 13: 175°C 14: 180°C
15: 185°C 16: 190°C
<Default value>
e-STUDIO557: 13
e-STUDIO657/757/857: 8
M
0: 100°C 1: 110°C 2: 120°C 3: 125°C 4: 130°C 5:
135°C 6: 140°C 7: 145°C 8: 150°C 9: 155°C 10:
160°C 11: 165°C 12: 170°C 13: 175°C 14: 180°C
15: 185°C 16: 190°C
<Default value>
e-STUDIO557/657:
TWD: 6
Others: 4
e-STUDIO757/857:
NAD/SAD: 6
Others: 4
M
0: 50°C 1: 55°C 2: 60°C 3: 65°C 4: 70°C 5: 75°C 6:
80°C 7: 85°C 8: 90°C 9: 95°C 10: 100°C 11: 105°C
12: 110°C 13: 115°C 14: 120°C 15: 125°C 16: 130°C
M
0: 5°C 1: 10°C 2: 15°C 3: 20°C 4: 25°C 5: 30°C 6:
35°C 7: 40°C 8: 45°C 9: 50°C