Mode
Element
Sub
element
08
Setting
Process
Fuser
Low-temperature
Mode
waiting
08
Setting
Process
Fuser
Low-temperature
Mode
waiting
08
Setting
Process
Fuser
Low-temperature
Mode
waiting
e-STUDIO557/657/757/857
Item
Subitem
Code Sub-
Additional
5412
temperature rising
period
Additional
5412
temperature rising
period
Additional
5412
temperature rising
period
Details
Default
Acceptable
code
value
value
3
Thick paper 1
Refer to
0~11
(Low temperature
contents
environment)
4
Thick paper 2
Refer to
0~11
contents
5
Thick paper 3
Refer to
0~11
contents
64
RAM
Contents
M
Sets for how many minutes the temperature is added
after warming-up in the low-temperature warming-up
control mode.
0: Not Added 1: 5 min. 2: 10 min. 3: 15 min. 4: 30
min. 5: 60 min. 6: 90 min. 7: 120 min. 8: 240 min. 9:
360 min. 10: 480 min. 11: Always Added
<Default value>
e-STUDIO557: 0
e-STUDIO657/757/857: 11
* The setting value of this code is applied when "1"
(enable) is set to the code 08-2226-3.
M
Sets for how many minutes the temperature is added
after warming-up in the low-temperature warming-up
control mode.
0: Not Added 1: 5 min. 2: 10 min. 3: 15 min. 4: 30
min. 5: 60 min. 6: 90 min. 7: 120 min. 8: 240 min. 9:
360 min. 10: 480 min. 11: Always Added
<Default value>
e-STUDIO557: 0
e-STUDIO657/757/857: 11
* The setting value of this code is applied when "1"
(enable) is set to the code 08-2226-4.
M
Sets for how many minutes the temperature is added
after warming-up in the low-temperature warming-up
control mode.
0: Not Added 1: 5 min. 2: 10 min. 3: 15 min. 4: 30
min. 5: 60 min. 6: 90 min. 7: 120 min. 8: 240 min. 9:
360 min. 10: 480 min. 11: Always Added
<Default value>
e-STUDIO557: 0
e-STUDIO657/757/857: 11
* The setting value of this code is applied when "1"
(enable) is set to the code 08-2226-5.