Download Print this page

Toshiba e-STUDIO556 Service Manual page 1296

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO556:

Advertisement

05/08
Mode
Element
Sub
element
08
Setting
Process
Fuser
Switching timing into
Mode
low-speed pre-
running from start of
ready status
08
Setting
Process
Fuser
Low-speed pre-
Mode
running starting
temperature during
ready status
08
Setting
Process
Fuser
Low-speed pre-
Mode
running stopping
temperature during
ready status
08
Setting
Process
Fuser
Low-speed pre-
Mode
running starting
temperature during
ready status
08
Setting
Process
Fuser
Low-speed pre-
Mode
running stopping
temperature during
ready status
08
Setting
Process
Fuser
Mode
e-STUDIO557/657/757/857
Item
Subitem
Code Sub-
2130
Pressure roller
2131
Pressure roller
2132
Pressure roller
2136
Pressure roller
2137
2147
Details
Default
Acceptable
code
value
value
Pressure roller
1
0~12
Option not installed
Refer to
0~16
(When setting 08-
contents
2130 is enabled)
Option not installed
Refer to
0~9
(When setting 08-
contents
2130 is enabled)
Option installed
Refer to
0~16
(When setting 08-
contents
2130 is enabled)
Option installed
Refer to
0~9
(When setting 08-
contents
2130 is enabled)
High fusing
0
0~1
mode(When thick
paper 2 is used)
11
RAM
Contents
M
0: Switching disabled 1: 5 min. 2: 10 min. 3: 20 min.
4: 30 min. 5: 40 min. 6: 50 min. 7: 60 min. 8: 70 min.
9: 80 min. 10: 90 min. 11: 100 min. 12: 120 min.
M
0: 50°C 1: 55°C 2: 60°C 3: 65°C 4: 70°C 5: 75°C 6:
80°C 7: 85°C 8: 90°C 9: 95°C 10: 100°C 11: 105°C
12: 110°C 13: 115°C 14: 120°C 15: 125°C 16: 130°C
<Default value>
e-STUDIO557: 3
e-STUDIO657:
JPC: 6
Others: 10
e-STUDIO757/857: 10
M
0: +5°C 1: +10°C 2: +15°C 3: +20°C 4: +25°C 5:
+30°C 6: +35°C 7: +40°C 8: +45°C 9: +50°C
<Default value>
e-STUDIO557: 9
e-STUDIO657/757/857: 5
M
0: 50°C 1: 55°C 2: 60°C 3: 65°C 4: 70°C 5: 75°C 6:
80°C 7: 85°C 8: 90°C 9: 95°C 10: 100°C 11: 105°C
12: 110°C 13: 115°C 14: 120°C 15: 125°C 16: 130°C
<Default value>
e-STUDIO557: 3
e-STUDIO657/757/857: 10
M
0: +5°C 1: +10°C 2: +15°C 3: +20°C 4: +25°C 5:
+30°C 6: +35°C 7: +40°C 8: +45°C 9: +50°C
<Default value>
e-STUDIO557: 9
e-STUDIO657/757/857: 5
M
The fusing efficiency level goes up during a continuous
printing (when Thick 3 is selected).
0: Disabled 1: Enabled
Proce
Servic
dure
e UI
1
1
1
1
1
1

Advertisement

loading