05/08
Mode
Element
Sub
element
Setting
Process
Fuser
Low temperature
08
Mode
waiting
08
Setting
Process
Fuser
Pre-running time for
Mode
first printing
e-STUDIO557/657/757/857
Item
Subitem
Code Sub-
Temperature setting
2030
2031
Details
Default
Acceptable
code
value
value
1
Thick paper 3
Refer to
0~12
contents
Thick paper 3
Refer to
0~15
contents
3
RAM
Contents
M
Sets the temperature at which low-temperature
warming-up control starts.
0: 130℃ 1: 135℃ 2: 140℃ 3: 145℃ 4: 150℃ 5:
155℃ 6: 160℃ 7: 165℃ 8: 170℃ 9: 175℃ 10:
180℃ 11: 185℃ 12: Disabled
<Default value>
e-STUDIO557: 5
e-STUDIO657: 11
e-STUDIO757/857: 10
* The setting value of this code is applied when "1"
(enable) is set to the code 08-2226-5.
M
0: Invalid 1: 1 sec. 2: 2 sec. 3: 3 sec. 4: 4 sec. 5: 5
sec. 6: 6 sec. 7: 7 sec. 8: 8 sec. 9: 9 sec. 10: 10 sec.
11: 12 sec. 12: 14 sec. 13: 16 sec. 14: 18 sec. 15: 20
sec
<Default value>
e-STUDIO557: 10
e-STUDIO657/757/857: 0
Proce
Servic
dure
e UI
4
1

Advertisement