Maintaining Mx480 Pics - Juniper MX480 Hardware Manual

Universal routing platform
Hide thumbs Also See for MX480:
Table of Contents

Advertisement

Figure 130: Installing an MPC
SC B
SC B
SEE ALSO
MX480 Modular Port Concentrator (MPC) Description | 151

Maintaining MX480 PICs

Purpose
For optimum router performance, verify the condition of the PICs.
Action
On a regular basis:
Check the LEDs on PIC faceplates. The meaning of the LED states differs for various PICs. For more
information, see the
MX Series Interface Module
failure, the FPC generates an alarm message to be sent to the Routing Engine.
Issue the CLI show chassis fpc pic-status command. The PIC slots in an FPC are numbered from 0 through
1, left to right:
user@host> show chassis fpc pic-status
Slot 0
Online
PIC 0
Online
PIC 1
Online
PIC 2
Online
PIC 3
Online
MX 48 0
Reference. If the FPC that houses the PIC detects a PIC
DPC 40x 1GE R
10x 1GE(LAN)
10x 1GE(LAN)
10x 1GE(LAN)
10x 1GE(LAN)
368