Table 14: AC Power Supply Electrical Specifications (continued)
Item
Efficiency
NOTE:
This value is at
full load and nominal
voltage.
High-Capacity Power Supplies
Maximum output power
AC input voltage
AC input line frequency
AC input current rating
Efficiency
NOTE:
This value is at
full load and nominal
voltage.
Table 15: AC Power System Specifications
Item
Redundancy
Output power (maximum)
per power supply
Output power (maximum)
per system
SEE ALSO
Specification
85% (low line and high line)
1167 W (low line)
2050 W (high line)
Operating range: 100 – 240 VAC (nominal)
50 to 60 Hz (nominal)
16 A @ 110 VAC maximum
15.1 A @ 200 VAC maximum
84% (low line)
89% (high line)
Normal
Capacity–Low
Normal-Capacity–High
Line
Line
3+1
2+2
1027 W
3200 W
3081 W
3200 W
High-Capacity–Low
High-Capacity–High
Line
Line
3+1
2+2
1167 W
2050 W
3501 W
4100 W