faceplate facing the body, and the other person slides the opening of the bag over the DPC connector
edge.
If you must insert the DPC into a bag by yourself, first lay the DPC horizontally on a flat, stable surface,
sheet metal side down. Orient the DPC with the faceplate facing you. Carefully insert the DPC connector
edge into the opening of the bag, and pull the bag toward you to cover the DPC.
Never stack a DPC under or on top of any other component.
SEE ALSO
MX480 DPC Terminology

Replacing an MX480 DPC

Removing an MX480 DPC | 329

1.
Installing an MX480 DPC | 331
2.
Removing an MX480 DPC
A DPC weighs up to 13.1 lb (5.9 kg). Be prepared to accept its full weight.
To remove a DPC (see
Figure 114 on page
1. Have ready a replacement DPC or DPC blank panel and an antistatic mat for the DPC. Also have ready
rubber safety caps for each DPC you are removing that uses an optical interface.
2. Wrap and fasten one end of the ESD grounding strap around your bare wrist, and connect the other
end of the strap to the ESD point on the chassis.
3. Label the cables connected to each port on the DPC so that you can later reconnect the cables to the
correct ports.
4. Use one of the following methods to take the DPC offline:
Press and hold the corresponding DPC online button on the craft interface. The green OK LED next
to the button begins to blink. Hold the button down until the LED goes off.
Issue the following CLI command:
user@host>request chassis fpc slot slot-number offline
331):