1. Calculate the power requirements (usage) using the values in
Router" on page 189
Table 87: Sample Power Requirements for an MX480 Router
Chassis Component
Base system
High-capacity cooling system
MPC - Slot 2
MPC - Slot 1
SCB 1
SCB 0
DPC - Slot 3
Zone 0 total output power
Zone 1 total output power
Zone 0 total output power (excluding cooling system)
Zone 1 total output power (excluding cooling system)
2. Evaluate the power budget. In the case of a DC-powered chassis, evaluate the budget for each zone.
In this step, we check the required power against the maximum output power of available power supply
options.
NOTE:
The power for the cooling system comes from a different tap on the power supply,
reserved for the cooling system only. The cooling system power requirement does not
need to be deducted from the output power budget of the power supply.
Table 88 on page 203
power deficit) for MX480 AC
output power, and unused power (or a power deficit) for MX480 DC chassis. See
as shown in
Table 87 on page
Part Number
MX480BASE-DC-HIGH
FFANTRAY-MX480-HC
MPC-3D-16XGE-SFPP-R-B
MPC-3D-16XGE-SFPP-R-B
SCBE2-MX with
RE-S-1800X2-8G
SCBE2 with
RE-S-1800X2-8G
DPCE-R-4XGE-XFP
lists the power supplies, their maximum output power, and unused power (or a
chassis.Table 89 on page 203
"Power Requirements for an MX480
202.
Power Requirement
40 W
160 W
440 W
440 W
185 W
90 W
185 W
90 W
310 W
1090 W
850 W
1010 W
770 W
lists the power supplies, their maximum
Zone
Zone 0 and Zone 1
Zone 0 and Zone 1
Zone 1
Zone 0
Zone 0
Zone 0
Zone 1
"AC Electrical