Connecting Dpc, Mpc, Mic, Or Pic Cables To The Mx480 Router - Juniper MX480 Hardware Manual

Universal routing platform
Hide thumbs Also See for MX480:
Table of Contents

Advertisement

To connect an external device to an alarm relay contact (see
1. Prepare the required length of wire with gauge between 28-AWG and 14-AWG (0.08 and 2.08 mm
2. While the terminal block is not plugged into the relay contact, use a 2.5-mm flat-blade screwdriver to
loosen the small screws on its side. With the small screws on its side facing left, insert wires into the
slots in the front of the block based on the wiring for the external device. Tighten the screws to secure
the wire.
3. Plug the terminal block into the relay contact, and use a 2.5-mm flat-blade screwdriver to tighten the
screws on the face of the block.
4. Attach the other end of the wires to the external device.
To attach a reporting device for the other kind of alarm, repeat the procedure.
Figure 81: Alarm Relay Contacts

Connecting DPC, MPC, MIC, or PIC Cables to the MX480 Router

To connect the DPCs, MPCs, MICs, or PICs to the network (see
Figure 83 on page
270):
1. Have ready a length of the type of cable used by the component. For cable specifications, see the
Series Interface Module
2. Remove the rubber safety plug from the cable connector port.
WARNING:
of fiber-optic cables. Fiber-optic transceivers and fiber-optic cables connected
to a transceiver emit laser light that can damage your eyes.
Reference.
Do not look directly into a fiber-optic transceiver or into the ends
Figure 81 on page
268):
Figure 82 on page 269
268
2
).
and
MX