6. Repeat the previous steps for any additional cables.
7. If the component is offline (its failure indicator LED is lit), use one of the following methods to bring
the it online:
To bring a DPC or an MPC online:
Press and hold the corresponding online button on the craft interface until the green OK LED next
to the button lights steadily, in about 5 seconds.
Issue the following CLI command:
user@host>request chassis fpc slot slot-number online
For more information about the command, see the
To bring a PIC online:
Press the PIC offline/online button until the PIC LED lights green. For a PIC installed in an FPC2
or FPC3, use a narrow-ended tool that fits inside the opening that leads to the button.
Issue the following CLI command:
user@host>request chassis pic fpc-slot fpc-slot pic-slot pic-slot online
For more information about the command, see the
To bring a MIC online:
Press the MIC offline/online button until the MIC LED lights green.
Issue the following CLI command:
user@host>request chassis mic fpc-slot mpc-slot pic-slot mic-slot online
For more information about the command, see the
The normal functioning indicator LED confirms that the component is online. You can also verify correct
DPC or MPC functioning by issuing the show chassis fpc command or correct MIC or the PIC functioning
by issuing the show chassis fpc pic-status command.
SEE ALSO
Preventing Electrostatic Discharge Damage to an MX480 Router | 477