Maintaining MX480 FPCs

Purpose
The MX480 router can have up to three Flexible PIC Concentrators (FPCs) installed horizontally in the
front of the chassis. For optimum router performance, verify the condition of the FPC.
Action
On a regular basis:
Check the LEDs on the craft interface directly above the FPC. The green LED labeled OK lights steadily
when an FPC is functioning normally.
Check the OK/FAIL LED on the FPC. If the FPC detects a failure, the FPC sends an alarm message to
the Routing Engine.
Issue the CLI show chassis fpc command to check the status of the installed FPC. As shown in the sample
output, the value Online in the column labeled State indicates that the FPC is functioning normally:
user@host> show chassis fpc
Temp
Slot State
(C)
0
Online
24
1
Empty
2
Online
41
3
Online
43
4
Online
24
5
Empty
For more detailed output, add the detail option. The following example does not specify a slot number,
which is optional:
user@host> show chassis fpc detail
Slot 0 information:
State
Temperature
Total CPU DRAM
Total RLDRAM
Total DDR DRAM
Start time:
Uptime:
Max Power Consumption
Slot 2 information:
State
CPU Utilization (%)
Total
Interrupt
3
0
9
0
5
0
3
0
24 degrees C / 75 degrees F
1024 MB
128 MB
2048 MB
368 Watts
Memory
Utilization (%)
DRAM (MB) Heap
1024
13
1024
15
1024
16
1024
13
Online
2008-12-11 16:53:24 PST
15 hours, 2 minutes, 47 seconds
Online
Buffer
21
57
57
21
338

Hide quick links: