Maintaining The Mx480 Host Subsystem - Juniper MX480 Hardware Manual

Universal routing platform
Hide thumbs Also See for MX480:
Table of Contents

Advertisement

Replacing an SSD Drive on an RE-S-1800 | 304
Replacing an SSD Drive on an RE-S-X6-64G | 306
Replacing Connections to MX480 Routing Engine Interface Ports | 312
Upgrading to the RE-S-X6-64G Routing Engine in a Redundant Host Subsystem | 314
Upgrading to the RE-S-X6-64G Routing Engine in a Nonredundant Host Subsystem | 320

Maintaining the MX480 Host Subsystem

Purpose
For optimum router performance, verify the condition of the host subsystem. The host subsystem comprises
an SCB and a Routing Engine installed directly into an SCB.
Action
On a regular basis:
Check the LEDs on the craft interface to view information about the status of the Routing Engines.
Check the LEDs on the SCB faceplate.
Check the LEDs on the Routing Engine faceplate.
To check the status of the Routing Engines, issue the show chassis routing-engine command. The output
is similar to the following:
user@host> show chassis routing-engine
Routing Engine status:
Slot 0:
Current state
Election priority
Temperature
CPU temperature
DRAM
Memory utilization
CPU utilization:
User
Background
Kernel
Interrupt
Idle
Model
Master
Master (default)
45 degrees C / 113 degrees F
43 degrees C / 109 degrees F
2048 MB
15 percent
0 percent
0 percent
8 percent
0 percent
92 percent
RE-S-1300
297

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents