Press the MIC offline/online button until the MIC OK/FAIL LED lights green.
Issue the following CLI command:
user@host> request chassis mic fpc-slot mpc-slot mic-slot mic-slot online
For more information about the command, see the
The normal functioning status LED confirms that the MIC is online. You can also verify correct MIC
functioning by issuing the show chassis fpc pic-status command described in
MICs" on page
351.
Figure 126: Installing a MIC
SEE ALSO
MX480 Modular Interface Card (MIC) Description | 136
Troubleshooting the MX480 MICs | 443
MX480 MIC Serial Number Label | 459
Installing an MX480 Dual-Wide MIC
To install a dual-wide MIC (see
1. Wrap and fasten one end of the ESD grounding strap around your bare wrist, and connect the other
end of the strap to the ESD point on the chassis.
2. Remove the septum, if necessary (see
a. Place the MPC on a flat surface (if necessary, remove the MPC from the router as described in
"Removing an MX480 MPC" on page
b. Remove the four screws labeled S on the bottom of the MPC.
c. Remove the two screws labeled S on the top of the MPC.
Figure 128 on page
360):
Figure 127 on page
363).
CLI
Explorer.
358):
"Maintaining MX480
357