Troubleshooting The Mx480 Mpcs - Juniper MX480 Hardware Manual

Universal routing platform
Hide thumbs Also See for MX480:
Table of Contents

Advertisement

PIC 1
Online
Slot 4
Online
PIC 0
Online
PIC 1
Online
PIC 2
Online
PIC 3
Online
For further description of the output from the command, see the
SEE ALSO
MX480 Modular Interface Card (MIC) Description | 136
Maintaining MX480 MICs | 351
Replacing an MX480 MIC | 352

Troubleshooting the MX480 MPCs

Problem
Description: The MPCs are not functioning normally.
Solution
Monitor the green LED labeled OK above the MPC on the craft interface as soon as an MPC is seated
in an operating router.
The Routing Engine downloads the MPC software to it under two conditions: The MPC is present when
the Routing Engine boots Junos OS, and the MPC is installed and requested online through the CLI or
push button on the front panel. The MPC then runs diagnostics, during which the OK LED blinks. When
the MPC is online and functioning normally, the OK LED lights green steadily.
Make sure the MPC is properly seated in the midplane. Check that each ejector handle has been turned
clockwise and is tight.
Check the OK/FAIL LED on the MPC and OK and FAIL line card LEDs on the craft interface. When the
MPC is online and functioning normally, the OK LED lights green steadily.
Issue the show chassis fpc command to check the status of installed MPCs. As shown in the sample
output, the value Online in the column labeled State indicates that the MPC is functioning normally:
user@host> show chassis fpc
1x 10GE XFP
MPC 3D 16x 10GE
4x 10GE(LAN) SFP+
4x 10GE(LAN) SFP+
4x 10GE(LAN) SFP+
4x 10GE(LAN) SFP+
CLI
Explorer.
444

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents