Description
All loaded Trays are visible and accessible. A Tray must be assigned to a
Tray Holder. A TrayTypeGroup identification checks if the specified Tray
Type is allowed in this combination. The offsets X-,Y-, Z and the inclination
corrections for a row or column are explained in the Utilities Functions
section.
The Path Offset X-,Y-, Z is used only if a Path is assigned to the specified
Tray Holder, typically a Stack or Agitator uses a Path.
The Wash Station and its positions Wash1 and Wash2 are visible and
selectable. Details , see
"Wash Stations"
The Firmware Objects accessed on the Extended User Mode have more
specific items selectable than at the User Level. Tolerances or ranges such
as Maximum Penetration can be defined and limited for the user so that
this value cannot be exceeded.
In the Tray Types Object, details for the various Items are described.
Furthermore, in this Firmware Object class a Valve and/or a Heater can be
assigned.
Note that the Wash Station Positions Waste and Waste2 are listed in this
Injectors class.
The Valves and Valve Drives connected and controlled by an AUX interface
are listed in this Object class. For more details, see the Valves and Valve
Drives Addendum.
Note that the valves controlled by serial communication (Serial Valves or
Multiposition Valves) are in the Firmware Object class Serial Valves.
The Firmware Objects accessed in the Extended User Mode have more
specific items selectable than at the User level. Tolerances or ranges such
as Maximum Fill Speed can be defined and limited for the user so that this
value cannot be exceeded.
Items such as Prime Volume, Waste to, Motor Drives, or Scale Length are
specific items that remain hidden at the User level.
The various positions used with the System are selectable at this level.
Positions such as Home, Change Syringe, or a Path Point, reference the
Paths for a specified Tray Holder directly, such as Agitator or Stack.
Selecting an item, e.g. Home will provide F1, Check Pos on the screen.
Activating this function provides the possibility of verifying X-, Y-, Z-axes
values for this particular position.
Agilent 1290 Infinity LC Injectors HTC/HTS User Manual
on page 144.