8. Appendix: SP Mode Tables
5415
Password Attack
Permissible Number
Sets the number of attempts to attack the system with random passwords to gain illegal
1
access to the system.
[0 to 100/30/1 attempt]
Detect Time
2
Sets the time limit to stop a password attack once such an attack has been detected.
[1 to 10/5/1 sec.]
5416
Access Information
Access User Max Number
Limits the number of users used by the access exclusion and password attack detection
1
functions.
[50 to 200/200/1 users]
Access Password Max Number
Limits the number of passwords used by the access exclusion and password attack detection
2
functions.
[50 to 200/200/1 passwords]
8
Monitor Interval
3
Sets the processing time interval for referencing user ID and password information.
[1 to 10/3/1 sec.]
5417
Access Attack
Access Permissible Number
Sets a limit on access attempts when an excessive number of attempts are detected for MFP
1
features.
[0 to 500/100/1]
Attack Detect Time
2
Sets the length of time for monitoring the frequency of access to MFP features.
[10 to 30/10/1 sec.]
3 Productivity Fall Wait