When line thickness more than 2 dots the value selected for SP2954-10 affects only the outer lines. The
diagram above shows "1" selected for SP2954-10. The setting does not affect the horizontal line.
2955
Binary Smoothing: Print
This SP controls the number of times that binary smoothing is performed.
1 2 Times
This SP switches double-smoothing ON/OFF
[0 to 2/2/1] [0 to 2/2/1]
2 3 Times
This SP switches triple-smoothing ON/OFF
[0 to 2/2/1]
VDB ID
Reads and displays the FPGA version 8-bit data of the VDB.
2959
Note: The VDB (Video Drive Board) controls the LPH. It processes the image information sent
from the IPU and sends it to the LPH.
8

SP3000 Process Control

3001
ID Sensor Initial Setting
PWM Setting: ID Sensor LED
1
Adjusts PWM. DFU
[0 to 100/20/0.01%]
Initialization
Automatically adjusts the output to 4.0 ±0.2V. During auto adjustment, the voltage applied to
the ID Sensor LED depends on the PWM value.
2
Press the Start button to initialize the ID sensor LED with the value entered for the PWM.
Initialization requires about 4 seconds.
Note: Do this SP cleaning the ID sensor and after replacement of the drum, ID sensor, NVRAM
and BCU.