6. At the left rear corner of the main machine, measure the distance [A] between the bridge unit and
main machine. (This should be about 49.5 to 50 mm.)
7. At the right rear corner of the main machine, measure the distance [B] between the bridge unit and
main machine. (This should be about 49.5 to 50 mm.)
8. The difference between the measured distances on the left and right ([A] – [B]) must not be more than
0.5 mm.
Folder FD6500B (Cross Folder) (B890)
2