Ricoh BE-C1 D046 Field Service Manual page 577

Table of Contents

Advertisement

2925
Transfer Current Timing DFU
Adjusts the timing of voltage on timing for paper separation at the leading/trailing edges for
different paper. Enter a minus setting for the voltage to apply earlier, enter a plus setting for
the voltage to apply later.
SP2925 Settings Table
Action
1
2
3
ON Timing
5
6
7
Action
10
OFF Timing
11
Action
15
16
17
OFF Timing
21
22
23
25 Transfer Current ON Timing
This SP sets the transfer current ON timing. This cannot be adjusted for each paper type (roll,
cut sheets, plain paper, translucent, etc.)
Source
Plain
Roll
Trans
Film
Plain
Cut
Trans
Film
Target
Leading Edge
Trailing Edge
Source
Plain
Roll
Trans
Film
Plain
Cut
Trans
Film
Type
[Range/Default/Step
[-5 to 10/0/1 mm]
[Range/Default/Step
[10 to 30/16/1 mm]
[-30 to 10/-8/1 mm]
Type
[Range/Default/Step
[0 to 35/8/1 mm]
System Service Mode
8
129

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Be-c1 d049

Table of Contents