2. Measure the side-to-side registration.
Standard
5±2.0 mm
3. Adjust side-to-side Registration for each paper feed station if necessary.
SP
1002-1
1002-2
1002-3
1002-4
1002-5
(5) Restoring the Printing and Scanner Erase Margin Setting
1. Restore the SP codes listed below to their original settings. (Refer to the SMC list printed earlier).
SP
2101-1
Printing Erase Margin – Leading Edge
2101-3
Printing Erase Margin – Left Edge
4012-5
Scanner Erase Margin – DF Leading Edge
4012-7
Scanner Erase Margin – DF Left
(6) Printer/Scanner Magnification
1. Copy an OS-A-1 Test Chart with plain paper (cut sheet or roll).
2. Measure the length and width of the image on the original and the copy.
Standard
3. If the measurements do not meet the standard, adjust the following SP codes.
SP4101-1
SP4008-1
Side-to-Side Registration - 1st Roll
Side-to-Side Registration - 2nd Roll
Side-to-Side Registration - 3rd Roll/1st Cassette
Side-to-Side Registration - 4th Roll/2nd Cassette
Side-to-Side Registration - By-pass feed
Name
Less than ± 0.5 %
Scanner Main Scan Magnification
Scanner Sub Scan Magnification
Name
5 to 2 (default)
5 to 2 (default)
0 to 1.5 (default)
0 to 1.5 (default)