Ricoh BE-C1 D046 Field Service Manual page 658

Table of Contents

Advertisement

8. Appendix: SP Mode Tables
The SP sets the default speed of the fan fold roller motor when the man machine is turned on.
[80 to 160/80/1 mm/s]
21 Skew at Folder Entrance
This SP can be adjusted to correct the reading of the paper length. The input from SP6962-1
(paper length) and SP6962-22 (paper offset) are used together. After two sheets of different
length have passed, the amount of skew and offset are calculated then corrected using this
equation:
Y = aX + b
where:
X: Actual paper length
Y: Paper length read by machine (SP6962-1)
a: Skew correction (SP6962-21)
b: Offset correction (SP6962-22)
[70 to 130/100/0.1 %]
22 Offset at Folder Entrance
This SP can be adjusted to correct reading of the paper length. The input from SP6962-1 (paper
length) and SP6962-021 (paper skew) are used together. After two sheets of different length
have passed, the amount of skew and offset are calculated then corrected using this equation:
8
Y = aX + b
where:
X: Actual paper length
Y: Paper length read by machine (SP6962-1)
a: Skew correction (SP6962-21)
b: Offset correction (SP6962-22)
[70 to 130/100/0.1 %]
31 Offset at Folder Exit
This SP adjusts the length of the fan folds in the paper to be sent to the cross fold unit.
[-10 to +10/0/0.1 mm]
41 Fold Motor Rotation
This SP adjusts the rotations of the fan fold motor.
[-10 to +10/0/0.1 %]
210

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Be-c1 d049