8. Appendix: SP Mode Tables
Note: This SP applies to the D046 only.
D046: [0 to 25/10/1]
3 Low Power Mode
Sets the fusing temperature for low power mode.
[80 to 150/90/1°C]
4 Lower Limit Edge Temperature DFU
This SP sets the lower limit for the value of the hot roller/pressure roller end temperature. If the
difference between the center and roller end temperature is greater than or equal to the value
of the SP code setting, the machine will suspend fusing until these temperatures are once rise
to acceptable levels.
Note: This SP applies to the D046 only.
[150 to 170/155/1°C]
Center Temp (SP1105-1).- End Temp (SP1105-2 ≥ SP1104
5 Fusing Temperature Calibration DFU
Calibrates the scale for the fusing temperature settings at the center of the hot roller.
[-10 to +10/0/1°C]
6 Pressure Temperature Calibration DFU
8
Calibrates the scale for the pressure temperature control at the center of the pressure roller.
[-10 to +10/1°C]
7 Pressure Temperature Calibration: Edge DFU
Calibrates the scale for the temperature control at the end of the pressure roller.
[-10 to +10/0/1°C]
8 Fusing Temperature Calibration: Edge DFU
Calibrates the scale for the temperature control at the end of the hot roller.
[-10 to +10/1°C]
Note: This SP applies to the D046 only. (The D046 has one hot roller end thermistor; the D049
has none.)
Fusing Temperature Display
1106
Displays the hot roller and pressure roller temperatures (°C)
84