1 Adjustment Ratio
Adjusts the percent of the increase in fusing motor speed. Normally, the speed of the fusing
motor is slightly faster to keep the paper taut and prevent skewing and wrinkling.
[0 to 18/10/1%]
2 Off Timing
After the registration roller starts turning to feed paper, just before the paper reaches the nip
of the fusing roller, the speed of the fusing motor is increased slightly while the paper is still in
the paper separation path. This raises the speed of the paper separation belt and prevents
skew.
This SP adjusts the length of time from when the speed of the fusing motor is increased to when
it returns to normal speed.
[180 to 230/205/5 mm)
1914
Fusing Pressure Motor DFU
1 Home Position Stop Mode
2 Pressure Adjustment: Right
3 Pressure Adjustment: Left
1915
Fusing Motor Speed-Down Adjustment DFU
This SP sets the rate of reduction in the fusing motor speed before the trailing edge of the paper
leaves the nip of the registration rollers.
[0 to -5/-0.4./0.02%]
Note:
• During paper feed to the fusing unit the fusing/exit motor speeds up slightly to keep the
paper straight and tight in the paper feed path.
• Before the trailing edge of the leaves the registration rollers, the speed of the fusing/exit
motor is reduced so the paper does not snap out of the registration nip quickly and cause
jitter in the image.
• Stretching the paper excessively could cause distortion of the image. This SP allows you
to correct this.
Resets the fusing pressure roller motor to the home
position.
[1 = ON, 0 = OFF]
Adjusts the pressure.
[-25 to +25/1]