TPM electronic authentication error
The attempt by the main machine to electronically authenticate TPM failed. When
SC878
B
the machine was switched on the value registered by TPM did not match the value
stored in the USB Flash Memory
• Replace the IOB.
File Format Converter (MLB) error
SC880
D
A request to get access to the MLB was not answered within the specified time.
• MLB defective, replace the MLB
Group 900
Electrical total counter error
The total counter contains something that is not a number.
• NVRAM incorrect type
SC900
D
• NVRAM defective
• NVRAM data scrambled
• Unexpected error from external source
Mechanical counter error
At the beginning of a count, the machine detected that the mechanical was not
connected.
SC901
D
Note: This function is provided only in EXP machines.
• Mechanical counter disconnected
• Mechanical counter connector loose or defective
SC910
External controller error 1
SC911
External controller error 2
B
SC912
External controller error 3
SC913
External controller error 4